Identify the connection
Provide pipe outside diameter and wall thickness. Confirm flange bore clearance and welding details against the approved drawing and project requirements.
LEKE PIPING / PRODUCTS
Slip-on flanges fit over the pipe before welding. Confirm the bore against the pipe outside diameter.

PRODUCT DETAILS
We can also make custom sizes, thicknesses and other dimensions to your drawing. Send your specifications with your RFQ so we can confirm the details.
| Parameter | Details to confirm |
|---|---|
| Connection | Pipe passes through the flange bore before welding |
| Dimensions | Confirm pipe outside diameter, flange bore, bolt pattern and thickness against the selected standard and drawing |
| Facing | Specify facing type, surface finish and mating flange or gasket requirements |
| Material | State the material specification, grade and required material test certificate |
Product dimensions, material grades and documentation are confirmed against your inquiry and applicable project requirements.
Primary dimensional reference: ASME B16.5 (NPS 1/2–24 where the type is covered). Confirm the product type, edition and applicable size before order.
DIMENSIONAL REFERENCE
Use the section view to identify the dimensions to confirm in your inquiry.

Symbols describe this supplied drawing. Confirm their correspondence with the selected standard and dimension table; notation may differ.
Any 1.6 mm facing height shown is specific to the supplied illustration. The applicable standard, pressure class and facing type determine the required value. This diagram does not define a universal facing height.
SELECTION & INQUIRY
Provide pipe outside diameter and wall thickness. Confirm flange bore clearance and welding details against the approved drawing and project requirements.
State the facing, pressure class and mating flange requirements.
Include the drawing revision, special machining or tolerances, inspection scope and required certificates.
TECHNICAL REFERENCES
ASME B16.5 / B16.47
Use the reference for the specified flange type, size and class. A large-diameter flange reference does not by itself establish slip-on dimensions; confirm the applicable standard or approved drawing.
Use the existing calculator for preliminary estimates. Confirm the final dimensions, material and actual product weight separately.
PRODUCT VIEWS
Compare the product views. Use the dimensional drawings and confirmed specifications for your order.
DIMENSIONAL REFERENCES
Reference data retained from the existing product page. Check the stated standard, edition, units and the approved project specification.
Product overview
Slip-on flanges are commonly considered where the pipe connection, material, size, standard and facing requirement need to be reviewed together. The flange slides over the pipe before welding.
Before quotation, provide the product size, material, applicable standard, pressure class, facing, quantity, destination and any drawings or documentation requirements.
Explore All FlangesListed product scope
| Size | 1/2″ to 48″ |
|---|---|
| Pressure class | Class 150 to Class 2500 |
| Materials | Carbon steel, stainless steel and alloy steel |
| Standards | ASME B16.5/B16.47, API 605, MSS SP44, DIN 2631–2637, EN 1092-1, GOST 12821-80, BS and JIS 2220 |
| Facing | RF, FF, RTJ, male/female and tongue/groove as applicable |
Final suitability, dimensions and documentation remain subject to the confirmed product and project requirements.
COMMON QUESTIONS
A slip-on flange slides over the pipe end and is secured with two fillet welds (one inside the bore and one on the back hub), making alignment simpler and lower in cost for low- to moderate-pressure lines. A weld neck flange has a long tapered hub that butt-welds directly to the pipe, offering higher fatigue strength and smoother flow for high-pressure, high-temperature, or cyclic-load service.
Provide the nominal pipe size (NPS or DN) and actual pipe outside diameter (OD), along with the governing flange standard (such as ASME B16.5 or EN 1092-1), pressure class or PN rating, facing type (RF or FF), and material grade. Because a slip-on flange bore is slightly larger than the pipe OD, confirming the exact pipe OD ensures proper fit-up before welding.
Only when approved by the piping engineer and permitted by the project code. While slip-on flanges share the same bolt-circle and facing dimensions as weld neck flanges of the same standard and pressure class, they have lower cyclic-fatigue strength and a different length-through-hub. Never substitute a slip-on flange for a weld neck flange in high-pressure, sour-service, or thermal-cycling systems without engineering sign-off.
Measure the outside diameter (OD), bolt circle diameter (BCD), number and diameter of bolt holes, bore diameter, flange thickness, and facing type (raised face height or flat face). If available, include photos of the rim markings (standard, size, pressure class, and material grade) so our team can match the exact specification.
We manufacture slip-on flanges in carbon steel (ASTM A105 / A350 LF2), stainless steel (ASTM A182 F304/304L, F316/316L), and alloy steel (F11, F22) to ASME B16.5, EN 1092-1, DIN, BS, and JIS standards. Every shipment can be supplied with EN 10204 3.1 mill test certificates, PMI reports, and third-party inspection (SGS, BV, or TÜV).
We support both trial/maintenance orders and full project packages with flexible MOQs depending on size and material grade. Standard sizes machined from stocked blanks ship quickly, while custom dimensions follow confirmed production schedules. All flanges are coated with anti-rust oil or specified paint, fitted with face protectors, and packed in seaworthy plywood cases or pallets.
Weld Neck FlangesReview the hub, bore and welding-end requirements.
View product details →
Lap Joint FlangesReview the flange and matching stub-end requirements.
View product details →
Plate FlangesReview the plate dimensions, bore and facing requirements.
View product details →
Blind FlangesReview closure dimensions, facing and bolt pattern.
View product details →
Socket Weld FlangesReview the socket, bore and connection dimensions.
View product details →
Threaded FlangesReview the required thread and facing details.
View product details →Send size, pipe outside diameter, standard and edition, class, facing, material grade and quantity. Include the drawing revision and required inspection documents.
SEND YOUR REQUIREMENT
Send your product list, specifications, or approval drawings—our technical sales team will review the details and return an itemized quote within 24 hours.
You do not need every specification finalized before reaching out—send what you have and we will confirm the rest with you.